60 days free credit available.
Fire door release locks.
And of course the maglocks can be released automatically by a fire alarm system in case of fire.
Thousands of customer product reviews.
03330 112 112 call 24 7.
Electric locks used on fire doors must be fail safe never fail secure that is the doors will automatically unlock during a fire to save lives rather than remain locked to protect property.
Key fobs and card reader units release switches digital keypads and emergency break glass units.
The magnetic hold must be tied to the fire alarm so the door will close automatically during a fire.
The exception being locks in childcare facilities which may be 1500mm 1650mm high as necessary.
Door lock heights on exit doors fire doors path of travel doors and disabled access doors now have a standardised lock height of 900mm 1100mm.
The door access control reader and the electric lock can be wired to the fire alarm in a number of different ways.
Choose from top trade brands.
Call 24 7 on.
03330 112 112 shop by product.
1 1 1 with the exception of fabric fire safety curtain assemblies this standard addresses assemblies that have.
Fire doors are essential safety devices in apartment blocks and workplaces designed to ensure maximum safety in emergencies and we have a comprehensive range of fire exit hardware designed to maximise the efficient functioning of your fire doors at all times.
With the addition of section 1008 1 9 8 electromagnetically locked egress doors the door mounted release device can be used instead of the sensor and emergency push button.
If door mounted hardware is used to release the electromagnetic lock the release devices are not required.
Door release hardware 1 except for dwelling units except for devices on doors serving a contained use areaor an impeded egress zone designed to be released in conformance with article 3 3 1 12 and except as permitted by sentence 4 locking latching and other fastening devices on every exitdoor shall permit the door to be.
The maglock devices are powered by a 12v power supply.
This standard regulates the installation and maintenance of assemblies and devices used to protect openings in walls floors and ceilings against the spread of fire and smoke within into or out of buildings.
This is a change from the 2009 edition.
Magnetic door lock kits can include the following release methods.
In the 2012 edition of the ibc electromagnetic locks may be used on doors with panic hardware as long as actuation of the panic hardware releases the electromagnetic lock.
A 1 1 see annex k for general information about fire doors.
Apple pay accepted in store.